ViBA

Computational Simulation of Respiration-Induced Deformation of Renal Arteries After EVAR.

Corvo A, Avril S, Aliseda A · Annals of biomedical engineering · 2025 · Article

10.1007/s10439-025-03806-y

Verified evidence

Model evaluation

3eb20635-4662-58b5-9d40-a877e76b1e07
Spatial localization error

Prediction source Version of record · PDF page(s) 7

Study 0362a9ec-105f-5197-8f7a-ba20020d430f · Prediction record (JSON)

Prediction fields

Comparator
observed_imaging · PDF page(s) 7
Concrete comparator
simulated graft centreline versus observed post-EVAR renal artery lumen centreline · PDF page(s) 6
Measured variable
renal_artery_stent_centerline · PDF page(s) 7
Measurement role
physiological_outcome · PDF page(s) 7
Population
human_observations · PDF page(s) 1, 7, 9
Reference type
observed_imaging_reference · PDF page(s) 7
Role
modeled_vs_observed · PDF page(s) 7
Scenario
same_case_clinical_reference · PDF page(s) 7

Validation Direct comparison · Same source · Sample overlap · Partial support · Matched conditions · Not applicable