Ventricular conduction and pacing

Four existing ViBA publications selected to illustrate how different definitions of ventricular activation affect cross-study interpretation. This is a worked example with one prediction per publication.

Reproduce the workflow

For four prespecified ventricular conduction papers, locate one reported prediction per paper, identify its evaluation source and physical PDF pages, and determine which reported findings can be compared.

  1. Open Electrophysiology and conduction. The release returned 88 prediction records across two API pages of up to 50 rows. The four selected predictions were present. The DOI filters returned one prediction each for Meiburg, Lange and Camps, and two for Tang. Use the linked prediction ID to select the intended Tang record.
  2. Repeat the endpoint search with each DOI. Open the linked prediction and use the result and validation-source pages in the evidence table.
  3. Display the four predictions side by side. Review the endpoint definition, time reference, comparator and source of evaluation before comparing findings.

The case provides source-page locators for evaluation context in all four papers. Camps has a linked same-source validation assessment in the prediction record. The Meiburg, Tang and Lange case entries document proposed in vivo evaluation, within-study sensitivity analysis and limited human evidence, respectively.

EvidenceMeiburg et al. (2023) Version of recordTang et al. (2026) Version of recordLange et al. (2016) Version of recordCamps et al. (2024) Accepted manuscript
ModelHuman mean-shape biventricular eikonal model coupled to CircAdapt. The geometry averages 100 healthy participants; the comparisons use one virtual geometry.PDF pp. 3, 4Reaction-eikonal electrophysiology in 24 anatomies with modelled proximal left bundle branch block (LBBB).PDF pp. 3, 4, 5, 6Human eikonal virtual population with a Purkinje network. Table 4 reports 70 ventricular geometries.PDF pp. 8, 9, 10, 12CMR-derived human biventricular digital twins with eikonal inference and monodomain simulation. Four control subjects and two subjects with hypertrophic cardiomyopathy.PDF pp. 2, 5, 8
ComparatorNon-selective left bundle branch pacing (nsLBBP) versus right ventricular apical pacing (RVAP). The paper also models selective LBB pacing, septal, biventricular and His-bundle pacing.PDF pp. 3, 4Nominal non-selective left bundle branch area pacing (LBBAP) versus right ventricular apical pacing (RVA), with a separate sinus-initiated LBBB control and proximal/distal pacing positions.PDF pp. 3, 4, 5, 6LBBB without a conductive false tendon versus LBBB with a modelled direct false tendon to the ventricular free wall. Healthy geometry and alternative insertions are also tabulated.PDF pp. 8, 9, 10, 12Simulated versus recorded 12-lead ECG of the same subject. The paper also contrasts root-node, minimal Purkinje and full Purkinje configurations.PDF pp. 2, 5, 8
EndpointRegional AT-95 (ms), the time to activate 95% of myocardial mass. Results are calculated separately for the left ventricular free wall, septum and right ventricular free wall.PDF pp. 3, 6BiV_TAT95 (ms), the node-weighted 95th percentile of activation times across both ventricles and the septum. The paper also reports LVAT95 for left ventricular nodes.PDF pp. 5, 6Simulated QRS duration (ms), defined as a myocardial activation-time surrogate.PDF pp. 10Pearson correlation of the simulated and clinical QRS waveforms. The results also describe QRS shortening with the full Purkinje configuration.PDF pp. 8, 10
Time windowElectrical activation during each simulated pacing scenario, evaluated up to 95% of regional myocardial mass.PDF pp. 3, 6From stimulus time zero to the 95th percentile on the simulation clock. The first ventricular activation time is retained in that clock.PDF pp. 5, 6From the first myocardial activation to complete myocardial activation.PDF pp. 10Manually delineated QRS complex of the averaged clinical ECG (20 beats) and the corresponding simulated waveform.PDF pp. 8, 10
Reported resultLeft ventricular free-wall AT-95 is shorter during nsLBBP than during RVAP (Figure 5); the plotted values are used for direction only.PDF pp. 5, 6Nominal LBBAP versus RVA: BiV_TAT95 93.5 versus 96.5 ms and LVAT95 85.5 versus 98.5 ms (group medians, Table 3). The reported median paired reduction in BiV_TAT95 is 2.5 ms (Table 4).PDF pp. 10, 11The mean surrogate duration was 131.9 ± 9.8 ms for LBBB without a false tendon and 105.8 ± 7.1 ms with direct attachment to the ventricular free wall (Table 4).PDF pp. 12Most eikonal configurations report waveform correlation above 0.8. The full Purkinje configuration shortened simulated QRS in the monodomain comparisons (Figure 6).PDF pp. 9, 10
Validation sourceClinical observations informed the simulation assumptions. The authors propose future in vivo comparison of the simulated measurements. The selected AT-95 contrast has no independent validation reported in the cited passages.PDF pp. 7, 9Within-study sensitivity analysis in three anatomies. The authors identify external patient-specific electrical validation as future work.PDF pp. 12, 13Previous literature supports the modelling approach. The authors report limited human evidence for direct validation of the false-tendon effect.PDF pp. 18Same-source comparison with clinical ECG. The target ECG is used during calibration. The selected results measure agreement with those data.PDF pp. 5, 8, 9

Which findings can be compared?

One of the six pairs supports comparison of the direction of the reported simulation results. The other five provide context only because the selected endpoints or contrasts differ.

Direction only · Meiburg et al. (2023) and Tang et al. (2026)

In both simulations, non-selective left bundle pacing shortened the selected left ventricular activation measure relative to right ventricular apical pacing. Meiburg measured time to activate 95% of left ventricular free-wall myocardial mass in a mean-shape model derived from healthy participants. Tang measured the 95th percentile of left ventricular nodal activation times from the pacing stimulus in models of proximal left bundle branch block. Tang's separate biventricular endpoint covers a different region. Differences in region, weighting and model setting make the timing effects unsuitable for pooling. Meiburg proposed future in vivo comparison. Tang reported a sensitivity analysis and identified external validation as future work.

Context only · Meiburg et al. (2023) and Lange et al. (2016)

Both report simulated myocardial activation times. Meiburg measures time to activate 95% of regional myocardial mass under different pacing strategies. Lange measures the interval from first to complete myocardial activation under different false-tendon configurations. The anatomical region, timing definition and contrast differ.

Context only · Meiburg et al. (2023) and Camps et al. (2024)

Both concern ventricular activation. Meiburg compares pacing strategies using regional activation time. Camps uses Pearson correlation between simulated and recorded QRS waveforms from the same subject, with those recordings informing calibration. The selected results address distinct quantities and comparisons.

Context only · Tang et al. (2026) and Lange et al. (2016)

Both model left bundle branch block. Tang compares pacing strategies and measures a nodal activation percentile from the stimulus. Lange compares false-tendon configurations and measures the interval from first to complete myocardial activation. The timing boundaries and contrasts differ.

Context only · Tang et al. (2026) and Camps et al. (2024)

Both concern simulated ventricular activation. Tang compares pacing strategies using time from the stimulus to a nodal activation percentile. Camps measures waveform agreement with the same subjects' recorded ECGs, which also informed calibration. The quantity, reference and contrast differ.

Context only · Lange et al. (2016) and Camps et al. (2024)

The studies use QRS to describe different quantities. Lange uses a simulated first-to-complete myocardial activation interval as a duration surrogate in a false-tendon contrast. Camps uses Pearson correlation between simulated and recorded QRS waveforms. The recorded ECGs also informed calibration, so the correlation measures agreement with the calibration source. These results provide context for how QRS was used in each study.

What each resource returned for this task

On 15 November 2026 UTC, we ran an endpoint search in ViBA and used the phrase ventricular activation in the three external searches. For the follow-up, we used the same four article DOIs and searched the two model repositories by full article title as well. The task was to obtain the selected prediction, its evaluation source and PDF page locators, and a pairwise decision.

ResourceTask entry and follow-upWhat the lookup returned
ViBAElectrophysiology and conduction. Filter by DOI and select the predefined prediction ID.Four selected prediction records with result and evaluation-context pages in the case export. The comparison shows six source-reviewed decisions.
Europe PMCVentricular activation in title or abstract, followed by four exact DOI searches.All four publications were found by DOI, with article or full-text links. The returned records provide the starting point for extracting the evidence from the papers.
BioModelsVentricular activation in model search, followed by article DOI and complete title.The endpoint search returned model entries. The DOI and title lookups returned no model entry for the four selected papers.
Physiome Model RepositoryVentricular activation in repository search, followed by article DOI and complete title.The endpoint search returned repository items. The DOI and title lookups returned no model entry for the four selected papers.

ViBA provides the source-linked predictions and evaluation context as a single comparison with reproducible locators and explicit limits. The external searches support article discovery or model discovery. This four-paper comparison describes the outputs of the recorded workflow. General search recall and repository coverage are outside its scope.

Download query inputs and observed results (JSON)

Source verification and reproduction

Join the four prediction IDs to ViBA's publication and PDF-source tables. Match each PDF to its stored SHA-256. Count PDF pages from the first file page, including any cover. Review the cited methods, results and limitations. Compare anatomical region, weighting, clock origin, pacing or disease contrast and validation source before interpreting any numerical result.

  1. Comparison of novel ventricular pacing strategies using an electro-mechanical simulation platform. · Version of record · Figures 2 and 5 PDF SHA-256 65a8e3d2f199d0847c3cf2ff237b50f39786f0ac1d8036c154978443f8f32ffa
  2. Effects of LBBAP pacing-site position under a modelled proximal LBBB: a 24-model electrophysiological simulation study. · Version of record · Tables 3 and 4, Figure 7 PDF SHA-256 903610bc0595ffe29e608576f785e11a6e000f3b995055ba1b535059e9de1197
  3. Protective Role of False Tendon in Subjects with Left Bundle Branch Block: A Virtual Population Study. · Version of record · Table 4 and Figure 6 PDF SHA-256 5d2e62f9bc38691147da8e365355ef4643800d316a5c0c336336f53b703b4c3e
  4. Digital twinning of the human ventricular activation sequence to Clinical 12-lead ECGs and magnetic resonance imaging using realistic Purkinje networks for in silico clinical trials. · Accepted manuscript · Table 1 and Figures 5 and 6 PDF SHA-256 01b550cf50ecd80713cc93ea8e6f1d3703ed83a22dc1a6721f69f61652c0e129