ViBA

Mechanistic Insights Into Inflammation-Induced Arrhythmias: A Simulation Study.

Bi X, Zhang S, Jiang H · Frontiers in physiology · 2022 · Article

10.3389/fphys.2022.843292

Verified evidence

Model scenario comparison

a49cfd59-13d7-54f8-b6ce-a7e5fbef055e
Electrophysiology and conduction

Prediction source Version of record · PDF page(s) 7

Study 4f9600a6-6fd1-5cbc-af72-5547c7f96233 · Prediction record (JSON)

Prediction fields

Concrete comparator
control, mild-inflammation, and inflammation simulations for the width of the vulnerable window · PDF page(s) 7
Endpoint
unidirectional_conduction_block_vulnerable_window_width__mean · PDF page(s) 7
Family
cardiac_electrophysiology · PDF page(s) 7
Measured variable
unidirectional_conduction_block_vulnerable_window_width · PDF page(s) 7
Measurement role
physiological_outcome · PDF page(s) 7
Metric
mean · PDF page(s) 7
Model
mechanistic_or_numerical · PDF page(s) 1, 12
Reference type
simulated_against_baseline · PDF page(s) 7
Role
simulated_output · PDF page(s) 7
Scenario
within_model_scenario_comparison · PDF page(s) 7